Modulys XL

The ultimate modularity for the most critical environments. Modular UPS from 200 to 4800 kVA/kW

The MODULYS XL is a modular UPS based on 200 kW power modules. The power of a single UPS unit can be increased up to 1200 kW and the system can include up to 4 units in parallel.
The innovative MODULYS XL concept allows for the constant protection of the load in online mode, whether to respond to load growth or to manage all aspects of the system’s lifecycle, in a secure way and with impressive rapidity.
Associated with a variety of adapted Services, the MODULYS XL provides unprecedented availability and flexibility to fulfil the requirements of today’s highly critical applications.

The solution for

• Data centres
• Buildings
• Industry

Advantages

3 standard bricks for your very own system

• UPS configurations based on 3 standard bricks for a simplified installation process.
• Repeatable and standardised assets to meet different configuration and architectural requirements.
• An adjustable number of empty power slots to match different scalability and redundancy needs.
• Complete UPS customisation without modifying the core standardised bricks.
• Quality, simplicity of construction and ease of operation.

5-minute plug-in

• Power module addition or removal in only 5 minutes by one person.
• Simple and safe power module plug-in: no power or communication bus cabling required.
• Load fully protected in double conversion mode during the power extension or module swap.
• Hot-scale and swap process in incremental steps of 200 kW to reduce time and optimise costs.
• Automatic power module self-configuration and testing before connection.
• Firmware auto-alignment.
• No installation rework when a new capacity is required.
• Off-powered connection of the power module to prevent electrical arcing upon plug-in and plug-out.

Safe and easy deployment

• Specifically engineered to eliminate unexpected installation errors.
• Easy power slot positioning and perfect alignment including on uneven floors.
• Power slots with pre-engineered built-in bus bars for quick, easy and clean interconnections.
• A full frontal access installation so the UPS can be installed against a wall.
• The power slots set up during the installation stage are ready for future hot plug-in power modules.
• Safe and easy power module handling.
• Full system heat-run test capability during commissioning without the need for an external load bench.

Concurrent and risk-free maintenance

• Concurrent maintenance of all components.
• Safe power module maintenance – outside of the running system.
• Both the power modules and the static bypass can be maintained while the load remains fully protected in double conversion mode.
• No in-situ maintenance, service or repair that may jeopardise the running system.
• Fully extractable power modules and subassemblies and complete access to all components, reducing the MTTR.
• Built-in means to perform an exhaustive pre-test after the module’s maintenance.

Preventive maintenance on UPS systems

Improving the reliability and durability of your critical power equipment

Ask for a FREE site survey! We‘ll install the correct UPS power systems for your site. We’re here to help you.

If you looking for continuous power control? Whatever UPS Power System you may require, our engineers will design the whole solution.

Flexible UPS architecture

• Hot-scalable power capability.
• Adjustable redundancy level.
• Common or separated rectifier and bypass mains.
• Compatible with different energy storage technologies (e.g. Li-Ion, Ni-Cd…).

Standard electrical features

• Separated inputs (rectifier, bypass).
• Top or bottom cable entry.
• Backfeed protection: detection circuit.
• Redundant bypass cooling.
• Distributed batteries (1 per module).
• Battery temperature sensor.
• Module heat-run test(1).
• Full system heat run test(1).
• 63 A three-phase plug.

Electrical options

• Input, output and maintenance bypass switches.
• 3-wire bypass and output distribution kit.
• PEN kit for TN-C grounding system.
• 4-wire rectifier (neutral connection kit).
• Shared batteries (1, 2 or 3 per unit).
• Enhanced battery charger.
• Battery tripping kit.
• Unit parallelisation kit.
• Redundant electronic power supplies.
• BCR (Battery Capacity Re-injection).
• ACS synchronisation system.
• Cold start.
• Top roof.

Standard communication features

• User-friendly 7” touch-screen multilingual colour graphic display (Power Hub).
• Tricolour display with a number indicating the Power Module status (Power Slot).
• 2 slots for communication options.
• USB port to download the UPS reports and log files.
• Ethernet port for service purposes.

Communication options

• Dry-contact interface (configurable, voltagefree contacts).
• MODBUS RTU RS485 or MODBUS TCP.
• PROFIBUS / PROFINET gateway.
• BACnet/IP interface.
• NET VISION: professional WEB/SNMP Ethernet interface for secure UPS monitoring and remote automatic shutdown.
• REMOTE VIEW PRO supervision software.
• IoT gateway for Socomec cloud services and the SOLIVE UPS mobile app.
• Remote touch-screen panel.
• Additional Com-slot extension.

Remote monitoring and cloud services

• LINK-UPS: Socomec’s 24/7 remote monitoring service connecting your installation to the nearest Socomec Service Centre.
• SOLIVE UPS: a mobile app to monitor all your UPS systems from a smartphone.

 

(1) Without dummy load bench.

UPS Unit
Power Module rated power200 kVA/kW
Unit rated power200 to 1200 kVA/kW
Number of Power Modules1 to 6
Number of Power Slots1 to 6
Number of Units per Systemup to 4 units in parallel
Redundant configurationN+x
Rectifier input
Voltage400 V 3ph (200 to 480 V(1))
Frequency50/60 Hz ±5 Hz
Power factor/THDI>0.99 / <2.5%(2)
Output
Power factor1 (according to IEC/EN 62040-3)
Voltage400 V 3ph+N (380/415 V configurable)
Frequency50/60 Hz (configurable) ±0.01 Hz – free-running
Voltage distortion (Ph/Ph)ThdU ≤ 1.5% (linear load)
Bypass
Voltagerated output voltage ±15% (configurable)
Frequencyrated output frequency ±5 Hz (configurable for Genset compatibility)
Power hub
Dimensions W x D x H1200 x 975 x 2120 mm
Weight750 kg
Power slot
Dimensions W x D x H550 x 975 x 2120 mm
Weight130 kg
Power module
Dimensions W x D x H500 x 950 x 1940 mm
Weight450 kg
TypeHot plug-in / Hot-swappable
MTBF1,000,000 hrs
Online efficiency (double conversion mode)up to 97%
Environment
Operating ambient temperaturefrom 0 °C to +40 °C
Relative humidity0-95 % without condensation
Maximum altitude1000 m without derating
Acoustic level at 1 m<75 dBA
Short-circuit withstanding (Icw)100 kA – Symmetrical
Standards
SafetyIEC/EN 62040-1
EMCIEC/EN 62040-2
PerformanceIEC/EN 62040-3
EnvironmentalIEC/EN 62040-4
Product declarationCE, EAC
(1) Conditions apply.
(2) At full rated voltage; with input THDV <1%.
UPS Selector
Find your UPS from 600 VA to 120 kVA.  Choose the best UPS solution for the current and future protection of your business.

Applications

Industry

Industry

Process manufacturing, Water treatment facilities, Machinery, Control room.

Healthcare

Healthcare

Operating theatres, intensive care units, laboratories, patient data systems, patient wards, examination rooms, sterilization rooms

Asset 2

Data Centres and Telecom

HVAC cooling units, Server room, Security Systems & Control rooms, Radio/TV stations

Infrastructure_1

Infrastracture

Airports, Harbours, Tunnels, Highways

Asset 1

Buildings

Commercial (Hotel, shopping centre, stadium, cinema, TV station, etc.), Government, Residential.