Masterys EM

Secure power supply for emergency systems. Three/single and three/three phase from 10 to 80 kVA

The EMergency CPSS range has been designed to answer your needs in terms of power supply for your safety system.

All our EMergency products are compliant with standard EN 50171.

The EMergency CPSS products are intended to ensure energy supply to emergency escape lighting in the event of main supply failure. Depending on the local legislation, it may be suitable for energizing other essential safety equipment, such as:
• electric circuits of automatic fire extinguishing installations;
• paging systems and signaling safety installations;
• smoke extraction equipment;
• carbon monoxide warning systems;
• special safety installations related to specific buildings, e.g. high-risk areas.

The wide range is suitable for all standard needs. For non-standard requests, our team of experts is on hand to adapt the products to your needs.

The solution for

• Airports
• Railways and bus stations
• Schools and universities
• Hospitals
• Shopping centers
• Cinemas and theatres
• Museums
• Public buildings
• Office buildings
• Hotels

Standard features

• IP20 metal enclosure compliant with EN 60598-1.
• Battery charging: 80% in 12 hours.
• Battery protection against the damage due to a polarity inversion.
• Battery protection against deep discharge.
• Long life battery with 10 years-life expectancy.
• Designed to withstand 120% of the nominal charge during the whole autonomy.
• Specific dry contacts & monitoring for EMergency system

Options

• Transformer embedded in the UPS enclosure (contact us for further information)
• Connection to downstream IT earthing system
• Eco mode to reach up to 98% of efficiency
• Other types of battery available

Preventive maintenance on UPS systems

Improving the reliability and durability of your critical power equipment

Ask for a FREE site survey! We‘ll install the correct UPS power systems for your site. We’re here to help you.

If you looking for continuous power control? Whatever UPS Power System you may require, our engineers will design the whole solution.

Sn [kVA]10152030406080
Pn [kW]913.51827365472
Pn according to EN 50171 [kW]7.511.31522.5304560
Input / output (3/1)
Input / output (3/3)
Input
Rated voltage400 V (3ph+N)
Voltage tolerance240 V to 480 V(1)
Rated frequency50 – 60 Hz
Frequency tolerance± 10 %
Power factor / THDI> 0.99 / < 3 %
Output
Rated voltage230 V (1ph+N) – 400 V (3ph+N)
Voltage tolerancestatic load ±1 % dynamic load in accordance with VFI-SS-111
Rated frequency50 – 60 Hz
Frequency tolerance± 2 % (configurable from 1 % to 8 %)
Overload UPS designed125% for 10 min, 150% for 1 min
Crest factor3:1
UPS Cabinet
Dimensions
W x D x H
444x795x1400 mm
Maximum weight with embedded battery515 kg
Maximum weight without battery120 kg124 kg127 kg138 kg158 kg120 kg211 kg
Protection degreeIP 20 (EN 50171)
Acoustic level 1m (ISO 3756)< 62 dBA
Battery
TypeVRLA with 10 years-life expectancy
Standard back up time at the end of battery life60/90/120 min(1)
Charging capabillity80 % of the autonomy in 12h
Embedded battery Max BUT (min)(1) – Load 25%280External battery
Embedded battery Max BUT (min)(1) – Load 100%60
Standards
CPSSEN 50171
SafetyIEC/EN 62040-1
EMCIEC/EN 62040-2
PerformanceIEC/EN 62040-3
Product declarationCE

(1) Condition apply

UPS Selector
Find your UPS from 600 VA to 120 kVA.  Choose the best UPS solution for the current and future protection of your business.

Applications

Industry

Industry

Process manufacturing, Water treatment facilities, Machinery, Control room.

Healthcare

Healthcare

Operating theatres, intensive care units, laboratories, patient data systems, patient wards, examination rooms, sterilization rooms

Asset 2

Data Centres and Telecom

HVAC cooling units, Server room, Security Systems & Control rooms, Radio/TV stations

Infrastructure_1

Infrastracture

Airports, Harbours, Tunnels, Highways

Asset 1

Buildings

Commercial (Hotel, shopping centre, stadium, cinema, TV station, etc.), Government, Residential.