Masterys BC+

Designed for easy integration and use
Three-phase UPS from 10 to 160 kVA

The solution for

• SME IT networking / computer rooms
• Control rooms
• Emergency service
• Payment systems
• Public sector
• Security control

Advantages

A flexible and cost-effective solution

• A compact range of standard product references with a variety of add-on options to adapt to every customer’s site.
• Easy to configure for retrofit in existing installations.
• Equipped with manual bypass breaker in standard mode.

Long back-up time engineered-in

• Several optimised choices for standard internal battery configuration.
• Increased internal battery density for reduced footprint and simplified installation.
• Internal basic back-up time available up 80 kVA, without additional external battery cabinet.
• High recharging current option for very long back-up time.

Embedded digital technology

• Digital Native UPS generation.
• IoT ready device for access to connected services.
• Easy integration in LAN/WAN and virtual environments.

Fast and easy installation

• A wide range of UPS from 10 to 160 kVA with the same performance and functionality.
• Free eRULER online sizing tool to get dimensions and electrical information in advance before installation.
• Tutored UPS installation with eWIRE mobile app.
• Quickly get online product documentation by simply inputting the Serial Number.

Fast delivery

• “Fast track manufacturing” option available for urgent projects or last-minute requirements.
• Fast delivery even for highly customised configurations thanks to easily combined options.

User and environmentally friendly

• 25+ languages available in the mimic panel.
• Ergonomics designed to simplify usage.
• Anticipates eco-regulations and is RoHS compliant.
• Units provided with wheels for easy positioning.

Preventive maintenance on UPS systems

Improving the reliability and durability of your critical power equipment

Ask for a FREE site survey! We‘ll install the correct UPS power systems for your site. We’re here to help you.

If you looking for continuous power control? Whatever UPS Power System you may require, our engineers will design the whole solution.

System features

• Dual input mains (30-40 kVA).
• Internal maintenance bypass switch.
• Input mains switch breaker.
• Output switch breaker.
• Auxiliary mains switch breaker.
• Backfeed protection: detection circuit.
• Power walk-in ramp for full compatibility with generators.
• Internal normal-life batteries.

Standard communication features

• 3.5” multilanguage graphic display.
• 2 slots for communication options.
• USB port for downloading log file.
• Ethernet port for service purposes.

System options

• 3-phase input without neutral.
• Internal backfeed isolation device.
• Common mains coupling bars.
• TN-C grounding system.
• ACS synchronisation system.
• IP21 degree of protection.
• Top cabling kit.
• Top ventilation kit.
• High capacity battery charger.

Communication options

• Dry-contact interface (configurable voltage-free contacts).
• MODBUS RTU RS485 or TCP.
• PROFIBUS / PROFINET gateway.
• BACnet/IP interface.
• NET VISION: professional WEB/ SNMP Ethernet interface for secure UPS monitoring and remote automatic shutdown.
• REMOTE VIEW PRO supervision software.
• IoT Gateway for Socomec cloud services and SOLIVE UPS mobile app.
• Remote touch-screen panel.

Remote monitoring service

• LINK-UPS: Socomec 24/7 remote monitoring service connecting your installation to the nearest Socomec Service Centre.
• SOLIVE UPS: mobile app enabling the monitoring of the UPS systems from a smartphone.

Technical data

 

Sn [kVA]10152030406080100120160
Pn [kW]913.5182736547290108144
Input / output 3/1
Input / output 3/3
Parallel configurationup to 6 units
Input
Rated voltage400 V 3ph+N (3 wire input also available on demand)
Voltage tolerance240 V to 480 V
Rated frequency50/60 Hz ± 10%
Output
Power factor0.9 (according to IEC / EN 62040-3)
Rated voltage1ph + N: 230 V (can be configured 220/240 V)
3ph + N: 400 V (can be configured 380/415 V)
Rated frequency50/60 Hz
Efficiency (TÜV SÜD verified)
Double conversion VFI modeup to 95%
Eco Modeup to 99%
Battery
TechnologiesVRLA, NiCd
Battery configurationinternalinternal
external
external
Internal back-up time (min)
Type B322139
Type M3362215
Type M411172452820
Type S496
Type T6139
Environment
Operating ambient temperatureup to +40 °C (2)
UPS Cabinet
Type B3 –
Dimension W x D x H
370 x 770 x 1170 mm
Type M3 –
Dimension W x D x H
370 x 770 x 1360 mm
Type M4 –
Dimension W x D x H
444 x 800 x 1400 mm
Type M6 –
Dimension W x D x H
600 x 855 x 1400 mm
Type T6 –
Dimension W x D x H
600 x 855 x 1930 mm600 x 855 x 1930 mm
Weightdepends on the number of batteries installed – contact us
Display3.5”
Degree of protectionIP20 (IP21 on demand)
Coloursmetallised grey E150HVR
Standards
SafetyIEC/EN 62040-1, AS 62040.1.1, AS 62040.1.2
EMCIEC/EN 62040-2, AS 62040.2
PerformanceIEC/EN 62040-3, AS 62040.3
Environmentalfull compliance with the RoHS EU directive
Product declarationCE, RCM (E2376)

(1) Max BUT @ 80% of the load.
(2) Conditions apply.

UPS Selector
Find your UPS from 600 VA to 120 kVA.  Choose the best UPS solution for the current and future protection of your business.

Applications

Industry

Industry

Process manufacturing, Water treatment facilities, Machinery, Control room.

Healthcare

Healthcare

Operating theatres, intensive care units, laboratories, patient data systems, patient wards, examination rooms, sterilization rooms

Asset 2

Data Centres and Telecom

HVAC cooling units, Server room, Security Systems & Control rooms, Radio/TV stations

Infrastructure_1

Infrastracture

Airports, Harbours, Tunnels, Highways

Asset 1

Buildings

Commercial (Hotel, shopping centre, stadium, cinema, TV station, etc.), Government, Residential.