Delphys MX
![](http://criticalpower.com.mt/wp-content/uploads/2021/01/delphysmx1.png)
Flexible transformer-based solution for resilient architectures. Three/three phase UPS from 250 to 900 kVA
The solution for
• Industry
• Processes
• Infrastructure
• IT applications
• Healthcare
Advantages
Optimum load protection
• Permanent operation in VFI mode (online double conversion).
• The inverter isolation transformer provides galvanic separation both between the DC current and the load and between the two sources.
• Output voltage precision under all load conditions.
• High overload capacity to withstand abnormal load conditions.
• Easy maintainability reduces MTTR thanks to pull-out sub-assemblies and front access to all components.
• Fault-tolerant architecture with built-in redundant components.
Flexible and easily upgradable
• Robust and reliable paralleling mode.
• Distributed or centralised bypass ensures perfect compatibility with any electrical infrastructure.
• Hot-plug capability simplifies extension or redundancy while keeping high quality power.
• The transformer based topology is adapted to all kinds of electrical installations.
Minimised Total Cost of Ownership
• High efficiency in VFI mode, including the transformer.
• High power density: its small footprint saves space on your premises.
• The high and constant input power factor helps limit the dimensions of your upstream network infrastructure.
• Mains connection of the rectifier requires only 3 cables (no neutral).
• High short-circuit capacity simplifies downstream protective devices.
![](http://criticalpower.com.mt/wp-content/uploads/2020/12/appli_724_a-b.jpg)
Preventive maintenance on UPS systems
Improving the reliability and durability of your critical power equipment
Ask for a FREE site survey! We‘ll install the correct UPS power systems for your site. We’re here to help you.
If you looking for continuous power control? Whatever UPS Power System you may require, our engineers will design the whole solution.
Parallel systems
• Distributed or centralized bypass for parallel architecture up to 6 units.
• Redundant systems (“1+1” and “n+1”).
• “2n” architecture with Static Transfer Systems.
Standard electrical features
• Slots for 3 communication cards.
• Backfeed protection: detection circuit.
• Standard interface:
– 3 inputs (emergency stop, generating set, battery protection),
– 4 outputs (general alarm, back-up, bypass, preventative maintenance needs).
Electrical options
• EBS (Expert Battery System)(2).
• ACS synchronisation system for 2n architecture.
• Redundant electronic power supplies.
• Hot plug option (increase the power keeping the load supplied in double conversion).
Mechanical options
• Reinforced IP protection degree.
• Dust filters.
• Fan redundancy with failure detection.
• Top entry connection.
Communication options
• GTS (Graphic Touch Screen).
• ADC interface (configurable voltage-free contacts).
• MODBUS RTU.
• MODBUS TCP.
• PROFIBUS / PROFINET.
• BACnet/IP interface.
• NET VISION: professional WEB/SNMP interface for UPS monitoring and shutdown management of several operating systems.
• 3 extra slots for communication cards.
Remote monitoring service
• LINK-UPS, remote monitoring service that connects your UPS to your Critical Power specialist 24/7
|
(1) Conditions apply.
(2) DELPHYS MX 250-500: others on demand.
(3) As per power range.
Applications
Industry
Process manufacturing, Water treatment facilities, Machinery, Control room.
Healthcare
Operating theatres, intensive care units, laboratories, patient data systems, patient wards, examination rooms, sterilization rooms
Data Centres and Telecom
HVAC cooling units, Server room, Security Systems & Control rooms, Radio/TV stations
Infrastracture
Airports, Harbours, Tunnels, Highways
Buildings
Commercial (Hotel, shopping centre, stadium, cinema, TV station, etc.), Government, Residential.