Delphys GP 2.0

High-efficiency protection without compromise
Three/three phase UPS from 160 to 1000 kVA/kW

The solution for

• Data centres
• Telecommunications
• Healthcare sector
• Service sector
• Infrastructure
• Industrial applications

Advantages

Energy Saving: high efficiency without compromise

• Offers the highest efficiency in the market using VFI – Double Conversion Mode, the only UPS working-mode that assures total load protection against all mains quality problems.
• Ultra high efficiency output independently tested and verified by an international certification organization in a wide range of load and voltage operating condition.
• Ultra high efficiency in VFI mode is provided by an innovative topology (3-Level technology) that has been developed for all the Green Power UPS ranges.

Full-rated power: kW=kVA

• No power downgrading when supplying the latest generation of servers (leading or unity power factor).
• Real full power, according to IEC 62040: kW=kVA (unity power factor design) means 25% more active power available compared to legacy UPS.
• Suitable also for leading power factor loads down to 0.9 without apparent derating.

Significant cost savings (TCO)

• Maximum energy saving thanks to 96% efficiency in true double conversion mode: 50% saving on energy losses compared to legacy UPS gives significant savings in energy bill.
• Up to 99% efficiency with FAST ECOMODE
• UPS “self-paying” with energy saving.
• Energy Saver mode for global efficiency improvement on parallel systems.
• kW=kVA means maximum power available with the same UPS rating: no overdesign cost and therefore less €/kW.
• Upstream infrastructure cost optimization (sources and distribution), thanks to high performance IGBT rectifier.
• Extended battery life and performance:
– long life battery,
– very wide input voltage and frequency acceptance, without battery use.
• EBS (Expert Battery System) charging management improves battery service life.
• BCR (Battery Capacity Re-injection) removes the constraints of using an additional load bank for the battery discharge test: it consists in re-injecting the energy stored in the batteries to other applications

Preventive maintenance on UPS systems

Improving the reliability and durability of your critical power equipment

Ask for a FREE site survey! We‘ll install the correct UPS power systems for your site. We’re here to help you.

If you looking for continuous power control? Whatever UPS Power System you may require, our engineers will design the whole solution.

Parallel systems

To fulfil the most demanding needs for power supply availability, flexibility and the installation to be upgraded:
• Modular parallel configurations up to 4 MW, development without constraint.
• Distributed or centralized bypass flexibility to ensure a perfect compatibility with the electrical infrastructure.
• Twin channel architecture with Static Transfer Systems.
• Distributed or shared battery for energy storage optimization on parallel systems.

Standard electrical features

• Integrated maintenance bypass for single unit (and 1+1 system).
• Backfeed protection: detection circuit.
• EBS (expert Battery System) for battery management.
• Redundant cooling.
• Battery temperature sensor.

Electrical options

• Seperated or common input mains.
• External maintenance bypass.
• Extended battery charger capability.
• Shared battery.
• Compatible with different battery technologies (e.g. Li-Ion, Ni-Cd…).
• Galvanic isolation transformer.
• Backfeed isolation device.
• ACS synchronisation system.
• BCR (Battery Capacity Re-injection).
• FAST ECOMODE.

Standard communication features

• User-friendly multilingual interface with graphic display.
• 2 slots for communication options.
• Ethernet connection (WEB/SNMP/email).
• USB port for event log access.

Communication options

• Advanced server shutdown options for stand-alone and virtual servers.
• 4 additional slots for communication options.
• ADC interface (configurable voltage-free contacts).
• MODBUS TCP.
• MODBUS RTU.
• BACnet/IP interface.

Remote monitoring service

• LINK-UPS, remote monitoring service that connects your UPS to your Critical Power specialist 24 / 7.

 

Sn (kVA)1602002503004005006008001000
Pn [kW]1602002503004005006008001000
Input / output3/3
Parallel configurationup to 4 MW
Input
Rated voltage400 V 3ph
Voltage tolerance200 V to 480 V(1)
Rated frequency50 / 60 Hz
Frequency tolerance± 10 Hz
Power factor/THDI> 0.99 / < 2.5%(3)
Output
Power factor1 (according to IEC/EN 62040-3)
Rated voltage3ph + N 400 V
Voltage tolerance static load±1% dynamic load in accordance with VFI-SS-111
Rated frequency50 / 60 Hz
Frequency tolerance± 2% (configurable for GenSet compatibility)
Total output voltage distortion – linear loadThdU < 1.5%
Total output voltage distortion – non-linear load (lEC 62043-3)ThdU < 3%
Short-circuit current(2)up to 3.4 x In
Bypass
Rated voltagerated output voltage
Voltage tolerance± 15% (configurable with from 10% to 20%)
Rated frequency50/60 Hz
Frequency tolerance± 2% (configurable for GenSet compatibility)
Efficiency
Online mode @ 40 % of loadup to 96%
Online mode @ 75 % of loadup to 96%
Online mode @ 100 % of loadup to 96%
Fast EcoModeup to 99%
Environment
Operating ambient temperaturefrom 0 °C up to +40 °C(1) (from 15 °C to 25 °C for maximum battery life)
Relative humidity0% – 95% without condensation
Maximum altitude1000 m without derating (max. 3000 m)
Acoustic level at 1m (ISO 3746)<65 dBA<67 dBA<70 dBA<72 dBA<74 dBA
UPS Cabinet
Dimensions W x D x H700 x 800 x 1930 mm1000 x 950 x 1930 mm1400 x 800 x 1930 mm1600 x 950 x 1930 mm2800 x 950 x 2060 mm3510 x 950 x 2060 mm3910 x 950 x 2060 mm
Weight470 kg490 kg850 kg900 kg1000 kg1500 kg2300 kg2800 kg3850 kg
Degree of protectionIP 20 (other IP as option)
Colourscabinet: RAL 7012, door: silver grey
Standards
SafetyIEC/EN 62040-1, AS 62040.1.1, AS 62040.1.2
EMCIEC/EN 62040-2, AS 62040.2
PerformanceIEC/EN 62040-3, AS 62040.3
Seismic compliance(4)
Uniform Building Code UBC-1997, EN 60068-3-3/1993 (seismic),
EN 60068-2-6/2008 (sinusoidal), EN 60068-2-47/2005 (mounting)
Product declarationCE, RCM (E2376)

(1) Conditions apply.
(2) Worst condition (Auxiliary Mains not available).
(3) With input THDV < 1%.
(4) 160, 200 and 500 kVA/kW models.

UPS Selector
Find your UPS from 600 VA to 120 kVA.  Choose the best UPS solution for the current and future protection of your business.

Applications

Industry

Industry

Process manufacturing, Water treatment facilities, Machinery, Control room.

Healthcare

Healthcare

Operating theatres, intensive care units, laboratories, patient data systems, patient wards, examination rooms, sterilization rooms

Asset 2

Data Centres and Telecom

HVAC cooling units, Server room, Security Systems & Control rooms, Radio/TV stations

Infrastructure_1

Infrastracture

Airports, Harbours, Tunnels, Highways

Asset 1

Buildings

Commercial (Hotel, shopping centre, stadium, cinema, TV station, etc.), Government, Residential.