MASTERYS GP 2.0

High-efficiency protection without compromise. Three/single and three/three phase from 10 to 40 kVA/kW

The solution for

• Data centres
• Telecommunications
• Healthcare sector
• Service sector
• Infrastructure
• Industrial applications

Advantages

Energy saving + Full rated power = TCO

Energy Saving: high efficiency without compromise

• Offers the highest efficiency in the market using VFI – Double Conversion Mode, the only UPS working-mode that assures total load protection against all mains quality problems.
• Ultra high efficiency output independently tested and verified by an international certification organization in a wide range of load and voltage operating conditions, to have the value in the real site conditions.
• Ultra high efficiency in VFI mode is provided by an innovative topology (3-Level technology) that has been developed for all the Green Power 2.0 UPS ranges.

Full-rated power: kW=kVA

• No power downgrading when supplying the latest generation of servers (leading or unity power factor).
• Real full power, according to IEC 62040: kW=kVA (unity power factor design) means 25% more active power available compared to legacy UPS.
• Suitable also for leading power factor loads down to 0.9 without apparent power derating.

Significant cost savings (TCO)

• Maximum energy saving thanks to 96% output efficiency: 50% saving on energy losses compared to legacy UPS gives significant savings in energy bill.
• UPS “self-paying” with energy saving.
• Energy Saver mode for global efficiency improvement on parallel systems.
kW=kVA means maximum power available with the same size of UPS, and therefore less €/kW
• Upstream infrastructure cost optimization (sources and distribution), thanks to high performance IGBT rectifier.
• Battery configuration can be optimized, thanks to a very wide DC range.
• Extended battery life and performance:
– long life battery,
– very wide input voltage and frequency acceptance, without battery use.
– EBS (Expert Battery System) charging management improves battery service life.”

Preventive maintenance on UPS systems

Improving the reliability and durability of your critical power equipment

Ask for a FREE site survey! We‘ll install the correct UPS power systems for your site. We’re here to help you.

If you looking for continuous power control? Whatever UPS Power System you may require, our engineers will design the whole solution.

Standard electrical features

• Dual input mains.
• Internal maintanance bypass.
• Backfeed protection: detection circuit.
• EBS (Expert Battery System) for battery management.
• Battery temperature sensor.

Electrical options

• External maintanance bypass.
• External battery cabinet.
• Additional battery chargers.
• Galvanic isolation transformer.
• Parallel kit.
• ACS synchronization system.

Standard communication features

• User-friendly multilingual interface with color graphic display
• Commissioning wizard.
• 2 slots for communication options.
• MODBUS TCP.
• MODBUS RTU.
• Embedded LAN interface (web pages, email).

Communication options

• Dry-contact interface.
• PROFIBUS
• BACnet/IP interface.
• NET VISION: professional WEB/SNM interface for UPS monitoring and shutdown management of several operating systems.

Remote maintenance

• LINK-UPS, remote monitoring service that connects your UPS to your Critical Power specialist 24/7.

Technical data

 

Sn [kVA]1015203040
Pn [kW]1015203040
Input / output 3/1
Input / output 3/3
Parallel configurationup to 6 units
Input
Rated voltage 400 V 3ph + N
Voltage tolerances240 V to 480 V(1)
Rated frequency 50/60 Hz ± 10%
Power factor/THDI> 0.99 / < 2.5%
Output
Power factor1 (according to IEC/EN 62040-3)
Rated voltage3ph + N: 400 V (can be configured 380/415 V)
Voltage tolerance static load ±1 % dynamic load in accordance with VFI-SS-111
Rated frequency 50 / 60 Hz
Frequency tolerance± 2% (configurable for GenSet compatibility)
Total output voltage distortion – linear load< 1 %
Total output voltage distortion – non-linear load< 3%
Overload125% for 10 minutes, 150% for 1 minute(1)
Crest factor 3:1
Bypass
Rated voltagerated output voltage
Voltage tolerance± 15% (configurable with from 10% to 20%)
Rated frequency 50 / 60 Hz
Frequency tolerance ± 2%
Efficiency (TÜV SÜD verified)
Online mode @ 50 % of loadup to 96%
Online mode @ 75 % of loadup to 96%
Online mode @ 100 % of loadup to 96%
Eco Modeup to 98%
Environment
Operating environment temperaturefrom 0 °C up to +40(1) °C (from 15 °C to 25 °C for maximum battery life)
Relative humidity0% – 95% without condensation
Maximum altitude1000 m without derating (max. 3000 m)
Acoustic level at 1 m (ISO 3746)< 52 dBA< 55 dBA
UPS Cabinet
Dimensions W x D x H444 x 795 x 800 mm444 x 795 x 1000 mm444 x 795 x 1400 mm
Weight190 kg195 kg315 kg320 kg
Degree of protectionIP 20
ColoursRAL 7012
Standards
SafetyIEC/EN 62040-1, AS 62040.1.1, AS 62040.1.2
Electromagnetic compatibility (EMC)IEC/EN 62040-2, AS 62040.2
PerformanceIEC/EN 62040-3, AS 62040.3
Seismic complianceOn demand according to Uniform Building Code UBC-1997 Zone 4
Product declarationCE, RCM (E2376)

 (1) Conditions apply

UPS Selector
Find your UPS from 600 VA to 120 kVA.  Choose the best UPS solution for the current and future protection of your business.

Applications

Industry

Industry

Process manufacturing, Water treatment facilities, Machinery, Control room.

Healthcare

Healthcare

Operating theatres, intensive care units, laboratories, patient data systems, patient wards, examination rooms, sterilization rooms

Asset 2

Data Centres and Telecom

HVAC cooling units, Server room, Security Systems & Control rooms, Radio/TV stations

Infrastructure_1

Infrastracture

Airports, Harbours, Tunnels, Highways

Asset 1

Buildings

Commercial (Hotel, shopping centre, stadium, cinema, TV station, etc.), Government, Residential.