Netys PR

High performance protection on rack or tower.Single/single phase UPS from 1700 to 3300 VA – Rack/Tower

The solution for

• Professional and IT equipment
• Servers and networking devices
• CAD/ Graphic workstations with monitors and peripherals
• Control systems

Advantages

A secure and professional supply continuity

• Ideal solution for protecting small servers, networking devices and peripherals.
• Assures service continuity to critical applications.
• Designed for professional applications: the sinevawe inverter technology assures full compatibility with any kind of load and power supply.

Tailored to IT networking

• The space and time-saving tower/rack conversion option means it can be installed easily either in tower mode or inside standard 19” rack cabinets depending on the user’s needs.

Simple to install

• No configuration needed on first startup.
• Compact footprint (2U/89 mm) for installation in rack cabinets.
• Attractive design for visible installation in offices.
• USB port and HID protocol as standard for direct interfacing with Windows systems®, without the need for additional specialist software.

Protection for your data line

• Integrated NTP protection for LAN/ADSL connection against the risk of data line overvoltage.

Meets practical needs

• Optional battery extension modules (EBM) to meet all back-up time requirements, even after installation.
• Clear and uncluttered LCD interface, with buzzers that immediately indicate the operating status of the UPS, even for less specialist users.
• Simplified maintenance and Battery `hot swap’, without closing down other applications.

Easy to use and to integrate

• Wide range of communication protocols available in options (including JBUS, TCP/ IP and SNMP) for integration into LAN networks or building management systems (BMS)
• Easy connections to the applications (depending on power) via 8 or 8+1 IEC 320 (IT standard) sockets.
• Load segmentation function to prioritize loads and manage critical situations.
• EPO (Emergency Power Off) emergency stop.
• RS232 advanced connections for the management of the power supply and local/ remote shutdown of applications.

Preventive maintenance on UPS systems

Improving the reliability and durability of your critical power equipment

Ask for a FREE site survey! We‘ll install the correct UPS power systems for your site. We’re here to help you.

If you looking for continuous power control? Whatever UPS Power System you may require, CPower engineers will design the whole solution.

Standard communication features

• LOCAL VIEW: ideal UPS monitoring and shutdown point-to-point solution for Windows®, Linux and Mac OS X operating systems.
• HID: UPS management based on Windows® embedded service – USB interface.
• MODBUS RTU (RS232).

Communication options

• NET VISION: professional WEB/SNMP interface for UPS monitoring and shutdown management of several operating systems.
• Dry-contact interface.
• Rails.

UPS and internal batteries

 

NETYS PR RT+ 1 (NPR-B1700-RT)+ 2 (NPR-B1700-RT)
1700 VA22 min42 min

NETYS PR RT+ 1 (NPR-B3300-RT)+ 2 (NPR-B3300-RT)
2200 VA37 min72 min
3300 VA22 min43 min

 


Connections

 

1. Fan / air vents
2. EPO Emergency Power Off
3. USB serial port
4. RS232 serial port
5. Connector for external battery extension

6. UPS output sockets (2 segments)
7. NTP protections (RJ45)
8. Slot for optional communication boards
9. Input socket
10. UPS full power output socket





 


Control panel

 

1. On / Off
2. Load present
3. Load level (5 steps)
4. General Alarm
5. Battery fault / Replace the battery
6. Overload
7. Battery capacity
8. Normal mode / Battery mode (flashing)
9. Automatic Voltage / Regulation active
10. Configuration
11. Programmable outlets
12. Input value
13. UPS test / Buzzer off
14. Navigator button
15. Enter

 

 

Technical data

 

Sn1700 VA2200 VA3300 VA
Pn1350 W1800 W2700 W
Input / output1/1  
Input
Rated voltage230 V
Voltage tolerances161 V ±4% (selecting wide mode) -276 V ±4%
Rated frequency50 / 60 Hz with automatic selection
Mains connectionIEC320-C14 (10 A)IEC320-C20 (16 A)
Output
Automatic Voltage Regulation (AVR)The AVR increases (boost 1) the output voltage by 14%
when the input voltage drops below 90% of the nominal value.
The AVR decreases (bucks) the output voltage by 12%
when the input voltage rises above 106% of the nominal value.
Rated voltage230 V ±5%
Rated frequency50/60 Hz ±0.1%
Power factor 0.9
@ 1500 VA
0.9
@ 2000 VA
0.9
@ 3000 VA
Wave formSine wave
ProtectionNormal Mode: overload (110% for 3 minutes)
Battery Mode: overload (110% for 30 seconds); shortcircuit protected
Sockets8 (10 A) x IEC 3208 (10 A) x IEC 320
1 (16 A) x IEC 320
Batteries
TypeSealed lead-acid maintenance free – expected life 3/5 years
Back-up time (1)6 min8 min6 min
Communication
InterfaceRS232 – USB
Ethernet adapterNET VISION (TCP/IP & SNMP) optional card
Local communication software Local View
Data line protectionNTP data line suppressor: RJ45 10 Base T
UPS Cabinet
Dimensions W x D x H440 x 436 x 87 mm440 x 608 x 87 mm
Weight18 kg28.2 kg31.5 kg
Standards
SafetyIEC/EN 62040-1, AS 62040.1.1, AS 62040.1.2
EMCIEC/EN 62040-2, AS 62040.2
Product declarationCE, RCM (E2376)

 (1) @ 75% of load 

UPS Selector
Find your UPS from 600 VA to 120 kVA.  Choose the best UPS solution for the current and future protection of your business.

Applications

Industry

Industry

Process manufacturing, Water treatment facilities, Machinery, Control room.

Healthcare

Healthcare

Operating theatres, intensive care units, laboratories, patient data systems, patient wards, examination rooms, sterilization rooms

Asset 2

Data Centres and Telecom

HVAC cooling units, Server room, Security Systems & Control rooms, Radio/TV stations

Infrastructure_1

Infrastracture

Airports, Harbours, Tunnels, Highways

Asset 1

Buildings

Commercial (Hotel, shopping centre, stadium, cinema, TV station, etc.), Government, Residential.