Netys RT

Total protection on rack or tower
Single/single phase UPS from 1100 to 11000 VA

The solution for

• Switching
• Storage
• Servers and networking devices
• VoIP communication systems
• Structured cabling systems
• Control systems
• Video surveillance systems

Advantages

High protection and availability

• Online double conversion technology with sinusoidal waveform.
• Permanent regulation of output voltage and frequency.
• Wide tolerance of the input voltage.

Simple to install

• No configuration necessary on first startup.
• Conversion mode for installation either in tower mode or inside standard 19“ rack cabinets.
• IEC input and output connections (1100‑3300 VA) or terminal input and output connections with built‑in magnetothermal input switch (5000‑11000 VA).
• Compact footprint.

Easy to use

• Clear and uncluttered SOCOMEC LCD interface.
• Wide range of communication protocols for integration into LAN networks or Building Management Systems (BMS).
• Load segmentation function to prioritize loads and manage critical situations.
• EPO (Emergency Power Off) emergency stop.
• Management of power supply and local / remote shutdown of the applications.

Meets practical needs

• Modular battery extension (EBM) to meet all back‑up time requirements, even after installation.
• 1+1 parallel redundant configuration (5000‑11000 VA).

Preventive maintenance on UPS systems

Improving the reliability and durability of your critical power equipment

Ask for a FREE site survey! We‘ll install the correct UPS power systems for your site. We’re here to help you.

If you looking for continuous power control? Whatever UPS Power System you may require, CPower engineers will design the whole solution.

Standard electrical features

• Built-in backfeed protection.
• RJ11 connection for Emergency Power Off (EPO).
• Connection for battery extension modules.
• Port for parallel operation (5000-11000 VA).

Electrical options

• 1+1 parallel module (5000-11000 VA).
• Manual bypass without interruption (5000-11000 VA).
• Battery extension modules.
• Hot-swap manual bypass (1100-3300 VA).
• Portable multiple German standard outlets with cable and IEC 320-C20 plug.

Standard communication features

• LOCAL VIEW: ideal UPS monitoring and shutdown point‑to‑point solution for Windows®, Linux and Mac OS X® operating systems.
• HID: UPS management based on Windows® and Mac OS X® embedded service ‑ USB interface (1100‑3300 VA).
• MODBUS RTU.
• RT-VISION: professional WEB/SNMP interface for UPS monitoring and shutdown management of several operating systems (5000-11000 VA).

Communication options

• RT-VISION: professional WEB/SNMP interface for UPS monitoring and shutdown management of several operating systems (1100-3300 VA).
• Dry-contact interface.
• Environmental Monitoring Device (EMD).

Connections
 
netysRT-175a-174a-76a-77a.jpg
1. Mains input socket (IEC 320)
2. Fan
3. Output socket (full power)
4. EPO (Emergency Power Off) input
5. RS232 interface (MODBUS protocol)
6. USB port
7. Input protection
8. Output sockets (IEC 320 – 10 A)
9. Battery extension connector
10. Slot for optional communication boards
11. Battery extension connector
12. Output terminals
13. Input terminals
14. Input switch
15. RJ45 LAN ethernet connector
16. Parallel port connector
 

Battery extension

 

Netys RT 1100-3300 VA – Battery extension

netys_115a-118d_gb.jpg (netys_118_d_gb)

 

 Netys RT 5000-11000 VA – Battery extension

netys_116a-119e_gb.jpg (netys_119_e_gb)

 

Control panel

 

netysRT-177-110a.jpg

1. Yellow LED lit. Operation in bypass mode
2. Green LED lit. Mains healthy
3. OFF button
4. Green LED lit. Normal operation (inverter in-line)
5. ON / TEST and buzzer override button
6. Navigator button
7. Alphanumeric LCD display
8. Green LED lit. Status of the load
9. Load status
10. Configuration
 

11. Programmable outlets
12. Battery status
13. Load level (5 steps)
14. Buzzer off
15. Load present
16. Battery fault / Replace the battery
17. General alarm
18. Overload
19. Input value
20. Normal mode / Battery mode (flashing)
 

 

Technical data

 

Power1100 VA / 900 W1700 VA / 1350 W2200 VA / 1800 W3300 VA / 2700 W5000 VA / 4500 W7000 VA / 5400 W9000 VA / 7200 W11000 VA / 9000 W
ArchitecturePFC and automatic bypassonline double conversion VFI with input
Parallel redundant function1+11+11+11+1
Input
Voltage230 V (1ph) 175÷280 V; up to 120 V @70% load 230 V (1ph) 181÷280 V; up to 100 V @50% load
Frequency50/60 Hz +/-10% (Auto-Selectable)
Power factor / THDi>0.99 / <5%
Output
Voltage230 V (1ph) selectable 200 / 208 / 220 / 240 V – 50 or 60 Hz + /- 2 % (+/- 0.05 Hz in battery mode)
Power factor0.9
@ 1000 VA
0.9
@ 1500 VA
0.9
@ 2000 VA
0.9
@ 3000 VA
0.9
@ 5000 VA
0.9
@ 6000 VA
0.9
@ 8000 VA
0.9
@ 10000 VA
Efficiency (online mode)up to 93%
Overload capabilityup to 105% continuously; 125% x 3 min; 150% x 30 secup to 105% continuously; 125% x 5 min; 150% x 30 sec
Output connections6 x IEC 320-C13 (10 A)6 x IEC 320-C13 (10 A) + 1 x IEC 320-C20 (16 A)terminals
Battery
Standard autonomy(1)8128108686
Voltage24 VDC48 VDC48 VDC72 VDC192 VDC192 VDC240 VDC240 VDC
Recharge time< 3h to recover 90% capacity< 6h to recover 90% capacity
Communication
Mimic panelLCD with graphical icons LCD with menu available in 6 languages
RS232 (DB9 port) Jbus protocol •
USB HID protocol
WEB/SNMP (Ethernet RJ45 port)optionoptionoptionoption
COMM slot
Dry contacts cardoptionoptionoptionoptionoptionoptionoptionoption
EPO input (RJ11 port)
Parallel port
Standards
SafetyIEC/EN 62040-1, AS 62040.1.1, AS 62040.1.2
EMCIEC/EN 62040-2, AS 62040.2
PerformanceIEC/EN 62040-3 (efficiency tested by an external independent body)
Product declarationCE, RCM (E2376)
Environment
Operating ambient temperaturefrom 0 °C to +40 °C (from 15 °C to 25 °C for best battery life)
Relative Humidity5-95% non-condensing
Noise level (ISO 3746)< 45 dBA<50 dBA< 55 dBA
Dimensions & weight
UPS size std W x D x H89 x 333 x 440 mm89 x 430 x 440 mm89 x 608 x 440 mm177.5 x 670 x 440 mm261 x 623 x 440 mm
UPS size RACK2U2U2U2U2U+2U2U+2U3U+3U3U+3U
UPS weight std13 kg18 kg19 kg30 kg15.5+40 kg16+40 kg19.5+66 kg20+66 kg
IP ratingIP20
EBM module size (W x D x H)89 x 340 x 440 mm89 x 438 x 440 mm89 x 610 x 440 mm89 x 608 x 440 mm130.5 x 623 x 440 mm
EBM module RACK2U2U2U2U2U2U3U3U
EBM module weight16 kg29 kg29 kg43 kg40 kg40 kg66 kg66 kg

(1) @ 75% of nominal load PF 0.7. 

 

 

Parallel redundant operation for business continuity

 

To achieve the highest level of availability and to power critical utilities, NETYS RT UPS modules above 3.3 kVA can be configured for 1:1 redundancy.
Redundant operation (1+1) means: the system incorporates one more UPS module than is needed to protect the load ; in the event of a breakdown, it guarantees sufficient power supply capacity to the load by maintaining online protection.
Parallel technology is based on the principle of load sharing, whereby both units are always kept active.
In a redundant configuration, overall system availability is much higher than a conventional UPS system using similar technology. 1+1 redundant configuration does not require additional circuits and can therefore be set up at a later date, simply by using two UPS modules and a collector / manual bypass module which simplifies cabling and maintenance of the UPS installation.
To further streamline the solution, it is also possible to select between operation with separate battery or shared battery, which is extremely useful in the case of applications requiring high levels of autonomy.

 
 
Converts from tower to rack mounted
 
UPS Selector
Find your UPS from 600 VA to 120 kVA.  Choose the best UPS solution for the current and future protection of your business.

Applications

Industry

Industry

Process manufacturing, Water treatment facilities, Machinery, Control room.

Healthcare

Healthcare

Operating theatres, intensive care units, laboratories, patient data systems, patient wards, examination rooms, sterilization rooms

Asset 2

Data Centres and Telecom

HVAC cooling units, Server room, Security Systems & Control rooms, Radio/TV stations

Infrastructure_1

Infrastracture

Airports, Harbours, Tunnels, Highways

Asset 1

Buildings

Commercial (Hotel, shopping centre, stadium, cinema, TV station, etc.), Government, Residential.